Company drill
Fire pump training drills that make the engineer react to change.
Good pump drills should include communications, changing demand and water-supply decisions—not just setting one pressure.
Five drill patterns
- Initial attack line, then add a second line without warning.
- Hydrant supply with a falling residual-pressure trend.
- Drafting setup with one planted troubleshooting problem.
- Master-stream deployment that forces a supply decision.
- Relay evolution with radio communication between pumpers.